Home › Heating, cooling and energy › Insulation Calculator

Insulation Calculator

Choose the R-value you want and the type of insulation. The calculator gives the installed thickness, the volume and how many bags or bundles to buy from the coverage on the package.

How it works

R-value measures how well a material resists heat flow. Higher is better. Each type of insulation gives a fairly steady R-value per inch, so the depth you need is the target R-value divided by the R-value per inch of your product.

thickness (in) = target R-value ÷ R-value per inch

bags or bundles = area ÷ coverage per package at that R-value (rounded up)

Manufacturers print a coverage chart on every bag of loose fill and every bundle of batts. It tells you how many square feet one package covers at each R-value. That chart is the most reliable figure for your product, so the calculator asks you for it.

Worked example

You want R-49 over a 1,000 sq ft attic floor with blown-in cellulose. At about R-3.5 per inch, R-49 needs 49 ÷ 3.5 = 14 inches (35.6 cm) of settled insulation, roughly 1,167 cu ft. If the bag chart says each bag covers 15 sq ft at R-49, you need 1,000 ÷ 15 = 66.7, so 67 bags. In metric terms, R-49 is about RSI 8.6.

Typical R-value per inch

ProductTypical range per inchUsed here
Fiberglass batts and rollsR-2.9 to R-3.8R-3.2
Blown-in celluloseR-3.2 to R-3.8R-3.5
Blown-in fiberglassR-2.2 to R-2.7R-2.5

Product labels always win over these averages. Batts are sold by their rated R-value, so for batts the bundle label tells you both the R-value and the thickness.

Depth needed for common targets

TargetFiberglass battsBlown celluloseBlown fiberglass
R-309.4 in8.6 in12 in
R-3811.9 in10.9 in15.2 in
R-4915.3 in14 in19.6 in
R-6018.8 in17.1 in24 in

Blown insulation settles over time. Coverage charts list an initial installed depth and a minimum settled depth. Blow to the initial depth so you still have the full R-value after it settles. Attic rulers stapled to the joists make the depth easy to check.

Batts or blown-in?

Batts and rolls suit open attics with regular joist spacing and few obstructions, and need no machine. They must be cut neatly around wires, pipes and framing; gaps and compressed areas lose a large share of their rated R-value. Blown-in loose fill flows around obstructions and into awkward corners, which makes it a better fit for attics with lots of wiring or irregular framing and for topping up existing insulation. It does need a blowing machine and a second person feeding the hopper.

Topping up existing insulation

Measure what is there and estimate its R-value, then insulate for the difference. For example, if the attic has old 3.5 in batts rated about R-11 and you want a total of about R-49, add about R-38: roughly 10.9 in of blown cellulose. In cold climates the current recommendation is a total near R-60, so you would add about R-49 instead: 14 in of cellulose. Lay new batts across the old ones at right angles, and use unfaced insulation on top so you do not trap moisture between layers.

Practical tips

  • Seal air leaks around plumbing stacks, light fixtures, wiring holes and the attic hatch before insulating. Insulation does not stop air.
  • Install baffles at the eaves so insulation does not block soffit vents.
  • Machine rental for blown insulation is often free or cheap with a bag purchase. It is a two-person job.
  • Insulation in walls is limited by stud depth: a 2×4 wall holds R-13 to R-15 batts and a 2×6 wall holds R-19 to R-21.

Safety and code

  • Wear a well-fitting dust mask or respirator, eye protection, gloves and long sleeves.
  • In the attic, step only on joists or boards laid across them. A foot through the ceiling causes injuries and costly repairs.
  • Keep insulation clear of chimneys, flues and recessed lights unless the fixture is rated for insulation contact (IC). Follow the clearances in local code.
  • If you find old knob-and-tube wiring, or gray-brown pebbly vermiculite that may contain asbestos, stop and call a professional.
  • Minimum R-values are set by local energy codes. Check them before you buy.

Frequently asked questions

How thick is R-30 insulation?

About 8.6 inches of blown cellulose, about 9.4 inches of fiberglass batts or about 12 inches of blown fiberglass, using the typical R-value per inch figures in this calculator.

How many inches is R-49 in the attic?

About 14 inches of blown cellulose or about 19.6 inches of blown fiberglass. Check the minimum settled thickness on the bag for your exact product.

Can I put new insulation over old insulation?

Usually yes, if the old insulation is dry and free of mold or pests. Use unfaced batts or loose fill on top, with no vapor barrier between the layers.

How do I convert R-value to RSI?

Multiply the US R-value by 0.1761. R-49 is about RSI 8.6. Australian products are labeled in metric R-values, which are RSI values.

Last updated November 8, 2026. See how we check our numbers.